Long-term evaluation of inserted nanocomposite hydrogel-based phosphorescent oxygen biosensors: evolution of local tissue oxygen levels and foreign body response
ACS Applied Bio Materials, Volume 7, Issue 6, pg. 3964-3980, May 2024
D Chimene, W Saleem, N Longbottom, B Ko, AS Jeevarathinam, S Horn, MJ McShane
[DOI]
Image-based evaluation of in vivo degradation for shape-memory polymer polyurethane foam
Polymers, Volume 14, Issue 19, pg. 4122, October 2022
LM Graul, SJ Horn, LD Nash, TB Cheung, FJ Clubb, Jr., DJ Maitland
[DOI]
Diffusable contrast-enhanced micro-CT improves visualization of stented vessels
Cardiovascular Pathology, Volume 60, pg. 107428, September 2022
AM Ginn-Hedman, TS Self, SL Jessen, CL Heaps, BR Weeks, FJ Clubb, Jr.
[DOI]
Correlation of light microscopic findings with transmission electron microscopy within a vascular occlusion device
Cardiovascular Pathology, Volume 50, pg. 107288, January 2021
AM Ginn-Hedman, SL Jessen, MC Friedemann, RM Nichols, DJ Maitland, FJ Clubb, Jr.
[DOI]
Histologic features of thrombosis events with a centrifugal left ventricular assist device
The Journal of Heart and Lung Transplantation, Volume 40, Issue 1, pg. 56-64, January 2021
SL Jessen, CN Kaulfus, K Chorpenning, AM Ginn-Hedman, D Tamez, BR Weeks
[DOI]
Iodine-enhanced micro-computed tomography of atherosclerotic plaque morphology complements conventional histology
Atherosclerosis, Volume 313, pg. 43-49, November 2020
TS Self, AM Ginn-Hedman, CN Kaulfus, AE Newell-Fugate, BR Weeks, CL Heaps
[DOI]
Micro-CT and histopathology methods to assess host response of aneurysms treated with shape memory polymer foam-coated coils versus bare metal coil occlusion devices
Journal of Biomedical Materials Research Part B: Applied Biomaterials, Volume 108, Issue 5, pg. 2238-2249, July 2020
SL Jessen, MC Friedemann, AE Mullen, AM Ginn-Hedman, SM Herting, DJ Maitland, FJ Clubb, Jr.
[DOI]
Microscopic Assessment of Healing and Effectiveness of a Foam-Based Peripheral Occlusion Device
ACS Biomaterials Science & Engineering, Volume 6, Issue 5, pg. 2588-2599, September 2019
SL Jessen, MC Friedemann, AM Ginn-Hedman, SM Jokerst, CB Robinson, TL Landsman, FJ Clubb, Jr., DJ Maitland
[DOI]
A self-cleaning, mechanically robust membrane for minimizing the foreign body reaction: towards extending the lifetime of sub-Q glucose biosensors
Journal of Materials Science: Materials in Medicine, Volume 30, pg. 1-11, July 2019
AK Means, P Dong, FJ Clubb, Jr., MC Friedemann, LE Colvin, CA Shrode, GL Coté, MA Grunlan
[DOI]
Introduction to Currently Applied Device Pathology
Toxicologic Pathology, Volume 47, Issue 3, pg. 221-234, April 2019
MC Friedemann, NA Mehta, SL Jessen, FH Charara, AM Ginn-Hedman, CN Kaulfus, BF Brocklesby, CB Robinson, SM Jokerst, AC Glowczwski, FJ Clubb, Jr., BR Weeks
[DOI]
Foreign Body Reaction to a Subcutaneously Implanted Self-Cleaning, Thermoresponsive Hydrogel Membrane for Glucose Biosensors
ACS Biomaterials Science & Engineering, Volume 4, Issue 12, pg. 4104-4111, October 2018
AA Abraham, AK Means, FJ Clubb, Jr., R Fei, AK Locke, EG Gacasan, GL Coté, MA Grunlan
[DOI]
Method for preclinical pathology evaluation and analysis of cardiovascular implantable electronic device implant sites
Cardiovascular Pathology, Volume 36, pg. 44-52, September 2018
SL Jessen, MT O’Brien, TW Lancon, HR Smith, LL Suarez, MD Wilcox, M Miller, BR Weeks, FJ Clubb, Jr.
[DOI]
Comparison of shape memory polymer foam versus bare metal coil treatments in an in vivo porcine sidewall aneurysm model
Journal of Biomedical Materials Research Part B: Applied Biomaterials, Volume 105, Issue 7, pg. 1892-1905, October 2017
JD Horn, W Hwang, SL Jessen, BK Keller, MW Miller, E Tuzun, J Hartman, FJ Clubb, Jr., DJ Maitland
[DOI]
Design and verification of a shape memory polymer peripheral occlusion device
Journal of the Mechanical Behavior of Biomedical Materials, Volume 63, pg. 195-206, October 2016
TL Landsman, RL Bush, AC Glowczwski, JD Horn, SL Jessen, E Ungchusri, K Diguette, HR Smith, SM Hasan, D Nash, FJ Clubb, Jr., DJ Maitland
[DOI]
A Method for Creating Artificial Thrombi In Vitro Using a Rotating Mechanical Surface
ASAIO Journal, Volume 62, Issue 3, pg. 252-260, May 2016
SL Jessen, AM Masse, MD Carpenter, FJ Clubb, Jr., BR Weeks
[DOI]
A brief review of ventricular assist devices and a recommended protocol for pathology evaluations
Cardiovascular Pathology, Volume 22, Issue 5, pg. 408-415, September 2013
BA Carpenter, CJ Gonzalez, SL Jessen, EJ Moore, AN Thrapp, BR Weeks, FJ Clubb, Jr.
[DOI]
Integrated microscopy techniques for comprehensive pathology evaluation of an implantable left atrial pressure sensor
Journal of Histotechnology, Volume 36, Issue 1, pg. 17-24, March 2013
A Roberts, KE Trainor, BR Weeks, N Jackson, RW Troughton, CJ Charles, MT Rademaker, IC Melton, IG Crozier, W Hafelfinger, DE Gutfinger, NL Eigler, WT Abraham, FJ Clubb, Jr.
[DOI]